Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-34175
Titel: | Quantification of Volatile Aldehydes Deriving from In Vitro Lipid Peroxidation in the Breath of Ventilated Patients |
VerfasserIn: | Müller-Wirtz, Lukas Martin Kiefer, Daniel Ruffing, Sven Brausch, Timo Hüppe, Tobias Sessler, Daniel I. Volk, Thomas Fink, Tobias Kreuer, Sascha Maurer, Felix |
Sprache: | Englisch |
Titel: | Molecules |
Bandnummer: | 26 |
Heft: | 11 |
Verlag/Plattform: | MDPI |
Erscheinungsjahr: | 2021 |
Freie Schlagwörter: | anesthesia breath analysis mechanical ventilation lipid peroxidation biomarker volatile aldehydes pentanal MCC–IMS ventilator-induced lung injury volatile organic compounds |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Exhaled aliphatic aldehydes were proposed as non-invasive biomarkers to detect increased lipid peroxidation in various diseases. As a prelude to clinical application of the multicapillary column–ion mobility spectrometry for the evaluation of aldehyde exhalation, we, therefore: (1) identified the most abundant volatile aliphatic aldehydes originating from in vitro oxidation of various polyunsaturated fatty acids; (2) evaluated emittance of aldehydes from plastic parts of the breathing circuit; (3) conducted a pilot study for in vivo quantification of exhaled aldehydes in mechanically ventilated patients. Pentanal, hexanal, heptanal, and nonanal were quantifiable in the headspace of oxidizing polyunsaturated fatty acids, with pentanal and hexanal predominating. Plastic parts of the breathing circuit emitted hexanal, octanal, nonanal, and decanal, whereby nonanal and decanal were ubiquitous and pentanal or heptanal not being detected. Only pentanal was quantifiable in breath of mechanically ventilated surgical patients with a mean exhaled concentration of 13 ± 5 ppb. An explorative analysis suggested that pentanal exhalation is associated with mechanical power—a measure for the invasiveness of mechanical ventilation. In conclusion, exhaled pentanal is a promising non-invasive biomarker for lipid peroxidation inducing pathologies, and should be evaluated in future clinical studies, particularly for detection of lung injury. |
DOI der Erstveröffentlichung: | 10.3390/molecules26113089 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-341754 hdl:20.500.11880/31391 http://dx.doi.org/10.22028/D291-34175 |
ISSN: | 1420-3049 |
Datum des Eintrags: | 17-Jun-2021 |
Bezeichnung des in Beziehung stehenden Objekts: | Supplementary Materials |
In Beziehung stehendes Objekt: | https://www.mdpi.com/1420-3049/26/11/3089/s1 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Anästhesiologie |
Professur: | M - Prof. Dr. Thomas Volk |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
molecules-26-03089-v2.pdf | 1,24 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons