Titel: Keratometry and the Central Radius with Aspheric Corneal Surfaces
VerfasserIn: Langenbucher, Achim
Wendelstein, Jascha
Cayless, Alan
Hoffmann, Peter
Szentmáry, Nóra
Sprache: Englisch
Titel: Current Eye Research
Bandnummer: 51 (2026)
Heft: 4
Seiten: 397-403
Verlag/Plattform: Taylor & Francis
Erscheinungsjahr: 2025
Freie Schlagwörter: Keratometry
central corneal radius
conoid surface model
corneal asphericity
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Purpose: To develop a simple concept for deriving the central corneal radius (RC) from the keratometry (K) or simulated keratometry (SimK) radius (RS) and corneal asphericity (QC), and to show the differences RC-RS based on a large dataset of measurements from a modern anterior segment tomographer. Methods: Comparing the local slopes of surface representations with a conoid and a reference sphere at the location of a keratometry measurement (diameter KD), RC and RC-RS can be derived as a function of RS, QC and KD. The differences RC-RS were evaluated for a large dataset containing measurements from the Casia 2 tomographer made before cataract surgery. Results: Depending on QC and KD, RC could deviate from the measured RS by up to 0.1 mm. With prolate corneas RS overestimates RC, and with oblate corneas RS underestimates RC. For example, with a typical cornea with RS = 7.7 mm and QC = -0.22 and a keratometer measuring at KD = 3 mm the central cornea is 0.0322 mm steeper (RC = 7.6678 mm) compared to keratometric measurement. Based on the dataset, the 95% confidence interval of RC-RS with KD = 3 mm was −0.0976 to +0.0265 mm. Conclusions: For corneal representations with a conoid surface or where central corneal radius is required e.g. for paraxial calculations, the keratometric radius of curvature could easily be converted to the central radius based on corneal asphericity and the keratometric zone diameter. With large positive or negative values of QC the differences RC-RS could be clinically relevant.
DOI der Erstveröffentlichung: 10.1080/02713683.2025.2596954
URL der Erstveröffentlichung: https://doi.org/10.1080/02713683.2025.2596954
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-484235
hdl:20.500.11880/42345
http://dx.doi.org/10.22028/D291-48423
ISSN: 1460-2202
0271-3683
Datum des Eintrags: 4-Aug-2026
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
Keratometry and the Central Radius with Aspheric Corneal Surfaces.pdf3,28 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons