Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-48604
Titel: Augmented stabilization of a rare geriatric "open book"-injury, using a cement augmented internal fixator - a case report
VerfasserIn: Stansell, Alexa
Pizanis, Antonius
Osche, David
Orth, Marcel
Liodakis, Emmanouil
Pohlemann, Tim
Fritz, Tobias
Sprache: Englisch
Titel: Trauma Case Reports
Bandnummer: 62
Verlag/Plattform: Elsevier
Erscheinungsjahr: 2026
Freie Schlagwörter: Open book injury
Pelvic ring fracture
Osteoporotic bone
Internal fixator
Minimally invasive stabilization pelvis
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background: Pelvic ring injuries in elderly patients, particularly in the context of low-energy trauma, typically involve posterior ring structures due to underlying osteopenia or osteopo rosis. However, symphyseal disruptions are extremely rare in this population. Pelvic ring injuries in elderly patients are increasingly common due to demographic changes, often resulting from low-energy falls. We present a unique case of a 77-year-old morbidly obese female with a Type B1.1 pelvic ring injury (APC-2, according to Young & Burgess classification), characterized by an open book lesion with no posterior fracture. Given the patient's body habitus and reduced bone quality, a minimally invasive internal fixator spine system was implanted and augmented with polymethylmethacrylate (PMMA) cement to enhance fixation strength and allow early mobilization. Case presentation: A 77-year-old female (BMI: 36 kg/m 2 ) presented with a rare isolated Type B1.1 pelvic ring injury (Fig. 1A) following a domestic fall. After emergency stabilization using an external fixator, in a secondary definitive surgery a subcutaneous internal fixator was implanted bilaterally in a minimally invasive fashion. To improve fixation in the osteoporotic supra- acetabular bone, the screws were cement-augmented using PMMA. The patient showed good postoperative recovery, early mobilization, and stable radiographic outcomes at 6 weeks follow- up. Conclusion: This case illustrates the feasibility and benefit of cement-augmented internal fixator of the pubic symphysis with a rare case of an “open-book” injury in elderly, obese female patient. Cement augmentation may offer additional pull-out strength in patients with reduced bone quality, facilitating early mobilization and avoiding complications related to implant loosening.
DOI der Erstveröffentlichung: 10.1016/j.tcr.2026.101327
URL der Erstveröffentlichung: https://doi.org/10.1016/j.tcr.2026.101327
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-486045
hdl:20.500.11880/42473
http://dx.doi.org/10.22028/D291-48604
ISSN: 2352-6440
Datum des Eintrags: 25-Aug-2026
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Chirurgie
Professur: M - Prof. Dr. Emmanouil Liodakis
M - Prof. Dr. Tim Pohlemann
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
1-s2.0-S2352644026000348-main.pdf7,14 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons