Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-47384
Titel: Comparison of corneal pachymetry evolution after accelerated corneal crosslinking in keratoconus eyes using anterior segment optical coherence tomography and Scheimpflug imaging
VerfasserIn: Lang, Antonia
Seitz, Berthold
Munteanu, Cristian
Flockerzi, Elias
Sprache: Englisch
Titel: International Ophthalmology
Bandnummer: 46 (2026)
Heft: 1
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2025
Freie Schlagwörter: Keratoconus
Corneal crosslinking
Corneal thickness
Scheimpflug
Optical coherence tomography
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Purpose This retrospective clinical study compared longitudinal corneal pachymetry measurement evolution after accelerated corneal crosslinking (A-CXL, 9 mW/cm2, 10 min) in keratoconus (KC) eyes as measured by Pentacam HR Scheimpflug imaging (Oculus, Germany) and Casia 2 (Tomey, Japan) anterior segment optical coherence tomography (AS-OCT). Methods 218 eyes covering the full topographic KC (TKC) severity spectrum that underwent A-CXL between 2017 and 2021 were examined at five time points (before, 6 weeks, 6 months, 1 year after A-CXL and at the latest follow-up) using both Pentacam HR and Casia 2. Central (CCT) and thinnest (TCT) corneal thickness were assessed. Corneal densitometry and TKC classification were assessed by Pentacam HR only. Intraoperative CCT evolution was monitored using ultrasound (Pachymeter SP-3000, Tomey, Japan) to ensure that CCT did not fall below 400 µm. Results CCT and TCT measured by Pentacam HR were significantly lower than preoperatively during the first postoperative year, while Casia 2 CCT and TCT measurements were not significantly lower than preoperatively at any time. The highest agreement of Pentacam HR and Casia 2 measurements occurred six weeks after A-CXL. Corneal densitometry peaked six weeks after A-CXL and decreased thereafter without reaching pre-A-CXL values. Ultrasound revealed significant CCT thinning during A-CXL. Conclusion Corneal Scheimpflug and AS-OCT based thickness measurements are not interchangeable. Corneal thinning after A-CXL detected by Pentacam HR was not observed in Casia 2 measurements. Since higher densitometry values did not correlate with a greater inter-device measurement difference, Scheimpflug-based corneal thickness measurements should be interpreted cautiously during the first year after A-CXL.
DOI der Erstveröffentlichung: 10.1007/s10792-025-03763-4
URL der Erstveröffentlichung: https://link.springer.com/article/10.1007/s10792-025-03763-4
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-473844
hdl:20.500.11880/41444
http://dx.doi.org/10.22028/D291-47384
ISSN: 1573-2630
Datum des Eintrags: 27-Mär-2026
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Prof. Dr. Berthold Seitz
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
s10792-025-03763-4.pdf931,68 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons