Please use this identifier to cite or link to this item:
doi:10.22028/D291-47384 | Title: | Comparison of corneal pachymetry evolution after accelerated corneal crosslinking in keratoconus eyes using anterior segment optical coherence tomography and Scheimpflug imaging |
| Author(s): | Lang, Antonia Seitz, Berthold Munteanu, Cristian Flockerzi, Elias |
| Language: | English |
| Title: | International Ophthalmology |
| Volume: | 46 (2026) |
| Issue: | 1 |
| Publisher/Platform: | Springer Nature |
| Year of Publication: | 2025 |
| Free key words: | Keratoconus Corneal crosslinking Corneal thickness Scheimpflug Optical coherence tomography |
| DDC notations: | 610 Medicine and health |
| Publikation type: | Journal Article |
| Abstract: | Purpose This retrospective clinical study compared longitudinal corneal pachymetry measurement evolution after accelerated corneal crosslinking (A-CXL, 9 mW/cm2, 10 min) in keratoconus (KC) eyes as measured by Pentacam HR Scheimpflug imaging (Oculus, Germany) and Casia 2 (Tomey, Japan) anterior segment optical coherence tomography (AS-OCT). Methods 218 eyes covering the full topographic KC (TKC) severity spectrum that underwent A-CXL between 2017 and 2021 were examined at five time points (before, 6 weeks, 6 months, 1 year after A-CXL and at the latest follow-up) using both Pentacam HR and Casia 2. Central (CCT) and thinnest (TCT) corneal thickness were assessed. Corneal densitometry and TKC classification were assessed by Pentacam HR only. Intraoperative CCT evolution was monitored using ultrasound (Pachymeter SP-3000, Tomey, Japan) to ensure that CCT did not fall below 400 µm. Results CCT and TCT measured by Pentacam HR were significantly lower than preoperatively during the first postoperative year, while Casia 2 CCT and TCT measurements were not significantly lower than preoperatively at any time. The highest agreement of Pentacam HR and Casia 2 measurements occurred six weeks after A-CXL. Corneal densitometry peaked six weeks after A-CXL and decreased thereafter without reaching pre-A-CXL values. Ultrasound revealed significant CCT thinning during A-CXL. Conclusion Corneal Scheimpflug and AS-OCT based thickness measurements are not interchangeable. Corneal thinning after A-CXL detected by Pentacam HR was not observed in Casia 2 measurements. Since higher densitometry values did not correlate with a greater inter-device measurement difference, Scheimpflug-based corneal thickness measurements should be interpreted cautiously during the first year after A-CXL. |
| DOI of the first publication: | 10.1007/s10792-025-03763-4 |
| URL of the first publication: | https://link.springer.com/article/10.1007/s10792-025-03763-4 |
| Link to this record: | urn:nbn:de:bsz:291--ds-473844 hdl:20.500.11880/41444 http://dx.doi.org/10.22028/D291-47384 |
| ISSN: | 1573-2630 |
| Date of registration: | 27-Mar-2026 |
| Faculty: | M - Medizinische Fakultät |
| Department: | M - Augenheilkunde |
| Professorship: | M - Prof. Dr. Berthold Seitz |
| Collections: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Files for this record:
| File | Description | Size | Format | |
|---|---|---|---|---|
| s10792-025-03763-4.pdf | 931,68 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License

